Mar 24, 2025
Here is a worksheet for calculating room combustion air.This is needed for when you want to run a single pipe system on a piece of equipment.
Combustion Air Calculation Worksheet for Single-Pipe System
Use the following steps to calculate the required combustion air for an appliance when operating with a single-pipe system:
-
Obtain the Appliance Input in BTUs.
-
Divide the BTU Input by 1,000.
-
Multiply the Result by 50.
-
The Final Result is the Required Cubic Feet of Combustion Air for the Space.